62 February 2018
>>>YOUR ELECTRONICS QUESTIONS ANSWERED HERE BY N&V READERS
is typically between 100 mA (0.1A)
and 1A (due to the limitations of the
magnetic detection circuitry), amp
clamp’s use is limited to measuring
power lines connected to large
devices (i.e., pump motors) that
naturally consume large amounts of
current in operation.
Ken Simmons
Auburn, WA
#2 An amp clamp is a transformer
having a one-turn primary (the
conductor carrying the current to be
measured) and a multi-turn secondary
(to feed the measuring instrument).
Being a transformer, it can only
be used to measure alternating
current. Be aware of its measurement
rating, because too much current
can saturate the clamp, resulting in
inaccurate readings.
The clamp is rated for sinusoidal
currents. Measurements of non-sinusoidal current is best done with
a true-RMS instrument connected to
the clamp secondary winding.
Currents small relative to the
capability of the clamp can be
measured by passing the conductor
through the clamp multiple times and
dividing the measured value by the
number of turns.
Peter A. Goodwin
Rockport, MA
#3 You are on the right track. The
ones that measure AC use a pickup
coil, and the ones that measure DC
use a Hall-effect sensor.
Chip Veres
Miani, FL
#4 The common AC current meters
use a transformer to measure the
current. The “clamp” is the core for
that transformer, and it is opened to
go around the AC wire as it becomes
the one-turn primary. There are simple
components to scale the multi-turn
secondary current down for the
correct reading — either analog or
digital. The digital part uses its own
circuit to convert the measurement to
its display.
A DC current meter cannot use
the same transformer method, so it
uses the Hall device that converts a
magnetic field to a resistance, and
the internal components convert that
resistance to a reading — analog or
digital.
Raymond Ramirez
Bayamon, PR
#5 I'm no expert, but you are